EPA Method 3C Determination of Carbon Dioxide, Methane, Nitrogen, and Oxygen From Stationary Sources

ID

6506ECBCC32846688F6C37F7F8EC9E5C

文件大小(MB)

0.03

页数:

4

文件格式:

pdf

日期:

2011-10-6

购买:

购买或下载

文本摘录(文本识别可能有误,但文件阅览显示及打印正常,pdf文件可进行文字搜索定位):

Method 3C—Determination of Carbon Dioxide, Methane, Nitrogen, and Oxygen From,Stationary Sources,1. Applicability and Principle,1.1 Applicability. This method applies to the analysis of carbon dioxide (CO2), methane (CH4),nitrogen (N2), and oxygen (O2) in samples from municipal solid waste landfills and other sources,when specified in an applicable subpart.,1.2 Principle. A portion of the sample is injected into a gas chromatograph (GC) and the CO2,CH4, N2, and O2concentrations are determined by using a thermal conductivity detector (TCD),and integrator.,2. Range and Sensitivity,2.1 Range. The range of this method depends upon the concentration of samples. The analytical,range of TCD's is generally between approximately 10 ppmv and the upper percent range.,2.2 Sensitivity. The sensitivity limit for a compound is defined as the minimum detectable,concentration of that compound, or the concentration that produces a signal-to-noise ratio of,three to one. For CO2, CH4, N2, and O2, the sensitivity limit is in the low ppmv range.,3. Interferences,Since the TCD exhibits universal response and detects all gas components except the carrier,interferences may occur. Choosing the appropriate GC or shifting the retention times by,changing the column flow rate may help to eliminate resolution interferences.,To assure consistent detector response, helium is used to prepare calibration gases. Frequent,exposure to samples or carrier gas containing oxygen may gradually destroy filaments.,4. Apparatus,4.1 Gas Chromatograph. GC having at least the following components:,4.1.1 Separation Column. Appropriate column(s) to resolve CO2, CH4, N2, O2, and other gas,components that may be present in the sample.,4.1.2 Sample Loop. Teflon or stainless steel tubing of the appropriate diameter.Note:Mention of,trade names or specific products does not constitute endorsement or recommendation by the U.,S. Environmental Protection Agency.,4.1.3 Conditioning System. To maintain the column and sample loop at constant temperature.,4.1.4 Thermal Conductivity Detector.,4.2 Recorder. Recorder with linear strip chart. Electronic integrator (optional) is recommended.,4.3 Teflon Tubing. Diameter and length determined by connection requirements of cylinder,regulators and the GC.,4.4 Regulators. To control gas cylinder pressures and flow rates.,4.5 Adsorption Tubes. Applicable traps to remove any O2from the carrier gas.,5. Reagents,5.1 Calibration and Linearity Gases. Standard cylinder gas mixtures for each compound of,interest with at least three concentration levels spanning the range of suspected sample,concentrations. The calibration gases shall be prepared in helium.,5.2 Carrier Gas. Helium, high-purity.,6. Analysis,6.1 Sample Collection. Use the sample collection procedures described in Methods 3 or 25C to,collect a sample of landfill gas (LFG).,6.2 Preparation of GC. Before putting the GC analyzer into routine operation, optimize the,operational conditions according to the manufacturer's specifications to provide good resolution,and minimum analysis time. Establish the appropriate carrier gas flow and set the detector,sample and reference cell flow rates at exactly the same levels. Adjust the column and detector,temperatures to the recommended levels. Allow sufficient time for temperature stabilization.,This may typically require 1 hour for each change in temperature.,6.3 Analyzer Linearity Check and Calibration. Perform this test before sample analysis. Using,the gas mixtures in section 5.1, verify the detector linearity over the range of suspected sample,concentrations with at least three points per compound of interest. This initial check may also,serve as the initial instrument calibration. All subsequent calibrations may be performed using a,single-point standard gas provided the calibration point is within 20 percent of the sample,component concentration. For each instrument calibration, record the carrier and detector flow,rates, detector filament and block temperatures, attenuation factor, injection time, chart speed,sample loop volume, and component concentrations. Plot a linear regression of the standard,concentrations versus area values to obtain the response factor of each compound. Alternatively,response factors of uncorrected component concentrations (wet basis) may be generated using,instrumental integration. Note: Peak height may be used instead of peak area throughout this,method.,6.4 Sample Analysis. Purge the sample loop with sample, and allow to come to atmospheric,pressure before each injection. Analyze each sample in duplicate, and calculate the average,sample area (A). The results are accep……

……